LDT060-1205-C2160W Class 2 Constant Voltage LED Driver

Features
- High Eciency (up to 88%)
- Constant Voltage Output
- Input Surge Protection: 2kV line-line, 4kV line-earth
- All-Around Protection: OVP, OCP, SCP, OTP
- Waterproof(IP67) and UL Dry / Damp / Wet Location
- Active Power Factor Correction
- Class2 and SELV
Download
Description
The LDT60 series is a 60W, Class 2 constant-Voltage outdoor LED Driverthat operates from 90-305 VAC input with excellent power factor. It iscreated for LED strip, LED module, LED landscape light. The high eciencyof these drivers and compact metal case enables them to run cooler,significantly improving reliability and extending product life. To ensuretrouble-free operation, protection is provided against input surge, outputover voltage, over current, short circuit, and over temperature.
Technical Information
60W Driver
MODEL NO | OUTPUT VOLTAGE | INPUT VOLTAGE RANGE | OUTPUT CURRENT RANGE | MAX OUTPUT POWER | TYPICAL EFFICIENCY* | POWER FACTOR 110VAC | 220VAC |
---|---|---|---|---|---|---|
LDT060-1205-C21 | 12V DC | 90 ~ 305 VAC | 0 ~ 5A | 60W | 84% | 0.99 | 0.96 |
Parameter | Min. | Typ. | Max. | Note |
---|---|---|---|---|
Input Voltage | 90 VAC | - | 305VAC | |
Input Frequency | 47 Hz | - | 63Hz | |
Leakage Current | - | - | <0.75mA | AT 277 VAC / 60Hz input, grounding effecttievly. |
Input AC Current | - | - | 1.0A |
Under 25°C±10°C ambient temperature, rated input and output range.
|
Inrush Current | - | - | <75A |
At 220 VAC input, 25°C cold start, duration = 1.2 ms, 10%lpk-10%lpk.
|
PF | 0.96 | - | - |
At 100-277 VAC, 100% load.
|
THD | - | - | 20% |
Parameter | Min. | Typ. | Max. | Note |
---|---|---|---|---|
Output Voltage Tolerance (full load) | -2.5% | - | 2.5% | At full load condition |
Output Voltage Tolerance (others) | -5% | - | 5% | Others. At full load condition. |
Ripple and Noise (pk-pk) | - | - | 2% Vo | Measured by 20Mhz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. |
Output Overshoot / Undershootshoot / Undershoot |
- | - | 10% | When power on or off. |
Line Regulation | - | - | ± 1% | |
Load Regulation | - | - | ± 2% | |
Turn-on Delay Time (110VAC) | - | 0.9s | 1.5s | Measured at 110VAC input. |
Turn-on Delay Time (220VAC) | - | 0.5s | 1.0s | Measured at 220VAC input. |
Load Dynamic Response (Output Deviation) | - | - | 50% V | R/S 1 A/uS Load: 25% - 75% full load. |
Load Dynamic Response (Settling Time) | - | - | 10ms | |
Temperature Coefficient | - | - | 0.02% / °C | Case temperature = 0°C - Tc max |